Hot search:
 

DC Hysteresis Graph Test System

Click on the image to check the artwork
unit price: negotiable
min amount:
amount:
period for delivery: Consignment Deadline Days
area: Hunan
Expiry date : Long Effective
last update: 2019-11-02 22:28
view count: 129
enquiry
Company Profile
 
 
Product details

DC Hysteresis Graph Test System

——MATS-2010SD Hysteresisgraph


Introduction

MATS-2010SD Hysteresisgraph can automatically measure the Magnetization Curve and Hysteresis Loop of soft magnets under static (DC) conditions. Precisely measure static magnetic parameters such as initial permeability μi, maximum permeability μm, saturation flux density Bs, remanence Br, coercivity Hc hysteresis loss Pu and so on.


Based on classic ballistic method principle, MATS-2010SD Hysteresisgraph combines the computer control technology and A/D, D/A, replace the conventional ballistic galvanometer with electronic integrator, achieve the analog ballistic measurement under microprocessor. It completely removes the non-instant error and is more accurate, faster and with a good repeatability. It removes various kind of artificial factors, offers a stable basis to study the magnetizing progress.


The test system confirms to GB/T 13012-2008, GB3657-83, GJB 937-90, JBT 9501-2002 and IEC 60404-4.


Test Items


1. Test closed circuit sample (ring, rectangle, EE, EI and U shape)

S/N

Test materials

Test parameters

Applied standards

1

Electric pure iron

Amorphous

/nanocrystalline

Permalloy

Electric steel(silicon steel)

soft ferrite

metal magnetic power core……

Initial permeability μi

Maximum permeability μm

Saturation flux density Bs

Remanence Br

Coercivity Hc

Hysteresis loss Pu

Basic magnetization curve

Hysteresis Loop

GB/T 13012-2008

IEC 60404-4

2

Hysteresis alloy

Relative hysteresis loss Pu corresponding to max permeability point.

Bulging coefficient Ku corresponding to max permeability point.

Magnetic field strength Hu corresponding to max permeability point.

Magnetic flux density Bu corresponding to max permeability point.

JB/T 14988-2008


2. Test open circuit samples( strip, sheet, rod)

S/N

Test materials

Test methods

Test parameters

Applied standards

1

Weak magnetic materials such as austenitic stainless steel

Solenoid

Relative permeability ur(1~4)

GJB 937-90

2

Temperature compensation alloy

Solenoid

Magnetic flux density B and its decrease according to temperature under the magnetic field of 8000A/m(100Oe).

JBT 9501-2002

3

Electric steel

Electric pure iron

Precision alloy

……

Permeameter

Magnetic flux density Bs

Remanence Br

Coercivity Hc

Hysteresis Loop

GB/T 13012-2008

4

Amorphous/nanocrystalline

Electric pure iron

Precision alloy

Solenoid

Magnetic flux density Bs

Coercivity Hc

No standard

5

Magnetic inks

Magnetic labels

Solenoid

Coercivity Hc

No standard


Features

➲Test sample category: soft ferrite, permalloy, amorphous, nanocrystalline, magnetic powder core, electric pure iron, silicon steel sheet and so on.

➲Test sample shape: closed circuit samples such as ring, E, U shape can directly winding and test.

➲Closed circuit sample directly winding and test: sample, excitation coil (N1), induction coil (N2) to form a non-load transformer.

➲Test open-circuit samples need solenoid or permeameter, the inner field of open circuit samples is measured by a built-in potentiometer(optional).

➲Measure the magnetic field by testing the magnetizing current, filed locking accuracy up to 0.1%.

➲Adopt electrical integrator to measure magnetic flux density, the integrator zero drift is self-corrected by software.

➲Measure methods: simulate shock (Sim. Shock in software) and magnetic field scan (M.F.Scan in software).

➲Adopt simulate shock to measure basic magnetization curve, it can accurately measure the magnetic parameters of μi, μm, Bs, μ of any point.

➲Adopt simulate shock and magnetic field scan to measure saturation hysteresis loop, it can accurately measure the magnetic parameters of Bs, Br, Hc, Pu. (Notes: Simulate shock to measure hysteresis loop is our company unique measurement method, which can greatly improve the accuracy of Hc and Pu.

➲Automatic demagnetizing before measuring μi, demagnetizing frequency is 1Hz~100Hz.

➲When select simulate shock method, single parameter can be selected to save time, thetime of every testing point can be set from 1 sec to 5 sec.

➲Adopt B speed feedback, which can automatically adjust the density of test point according to sample magnetic characteristics curve, and curve can also be tested according to testing points predefined by users.


Technical Data

1. Hardware Parameters

1.1 MATS-2010SD Hysteresisgraph

Model

MATS-2010SD/k50

MATS-2010SD/k100

Max. Output power

500VA

1000VA

Output voltage

0~±50V

0~±50V

Output current

1mA~10A, thirteen automatic ranges

2mA~20A, thirteen automatic ranges

Current fineness

< 0.1%*current range

Current stability

Superior to 0.05%

Flux range

0.25, 0.5, 1, 2, 5, 10, 20 mWb, seven automatic ranges

Fluxmeter sensitivity

0.05μWb (Sin. Shock); 0.1μWb (M. F. Scan)


1.2 PC-6616 Data Acquisition Card

Parameters

Specifications

A/D convert

16Bit, 8 channels differential input

Convert time

< 10μs

Convert accuracy

0.01% (full range)

D/A convert

16Bit, 2 channels independent output

Convert accuracy

0.01% (full range)



2. Excitation Devices (Optional)

2.1 LXG-0530 Standard Solenoid

Parameters

Specifications

Applied standards

GJB 937-90

Measured parameter

Relative permeability ur

Test sample type

Strip, rod, sheet

Length

50cm

Max. Magnetic field

30kA/m

Sample specification

L/D ratio>1:20


2.2 ES-700 Epstein Frame

Parameters

Specifications

Applied standards

GB3655-2008 and IEC 60404-2

Application

Measure DC magnetic characteristics of silicon steel sheet.

Equivalent magnetic circuit

940mm

Turns

N1=N2=700 turns

Sample size

Width:30mm±0.2mm; length:280~320mm±0.5mm

Sample mass

240g~1000g

Applied frequency

DC~400Hz


2.3 Type A Permeameter (two fluxmeters built in test main frame)

Parameters

Specifications

Applied standards

GB/T 13012-2008

Measured parameters

Saturation magnetic induction Bs

Sample types

Strip, rod, sheet

Max. Magnetic field

120kA/m

Sample specification

Length>250mm


2.4 Customized permeameter(according to customer requirements)

Parameters

Specifications

Reference standards

GB/T 13012-2008

Measured parameters

Saturation magnetic induction Bs

Sample types

Customized according to sample shape and size.

Max. Magnetic field

30kA/m

Sample specification

Customized according to sample shape and size.


System Parameters

1. Working Environment

Parameters

Specifications

Input power

Sigle-phase220V, 50Hz

Environment

Temperature: 23±5℃; Humidity:30~75%RH

External magnetic field interference

Absolutely avoid

Thermal balance time

10 minutes


2. System Technical Data

2.1 According to National Standard GB/T13012-2008, adopt Sin. Shock method to measure standard ring sample (ferrite), technical data are as follows:

Measured parameters

Bs(%)

Br(%)

Hc(%)

μm(%)

μi (%)

Uncertainty (k=2)

1

1

1.5

2

5

Repeability (constant temperature)

± 0.5

± 0.5

± 0.5

± 1

± 3


2.2 According to Military Standard GJB937-90, adopt Solenoid to measure open circuit weak magnetic material sample, technical data are as follows:

Measured parameters

μr (%)

Uncertainty (k=2)

2

Repeability (constant temperature)

±1.0


2.3 According to National Standard GB/T13012-2008, adopt type A Permeameter to measure open circuit soft magnet sample, technical data are as follows:

Measured parameters

Bs (%)

Uncertainty (k=2)

2

Repeability (constant temperature)

±1.0


◆ SMTest Test Software

1. System and Language

➲SMTest runs in Windows 7 operating system, confirms to Windows software standards, easy to operate.

➲Chinese, English operating interfaces can be selected.

➲Multiply units can be selected to meet the use habits of different customers.



2. Test Functions

➲Support Sin.Shock and M. F. Scan. Test process automatically control, intelligent judgement, no need user intervention.

➲Real time monitor sampling waveform and instrument status in test process, and can be stopped at any time.


➲Support sample shape parameter input of ring, EE, EI, CD, rectangle, diplopore, BS and others.

➲Calculate Ae and Le according to sample size.








3. File and Data Management

➲File system adopts data base, it can directly print or output test results into Excel.

➲File management with powerful functions, it can automatic save data, delete data and delete all data.

➲Data file contains full sampling data, sample parameters and instrument parameters. The file is in text format, and can input to other software.

➲It can display B(H) magnetization curve, B(H) hysteresis loop, μ(H) permeability curve, and display coordinate of each point on the curve.



4. Test Report and Data Export

➲Support all types of printers, test report and printer paper match perfectly.

➲With function of print preview, convenient to adjust the size of test report.

➲Directly print test report, or generate the test report into JPG file.

➲Send JPG file by E-mail, or save it into disk.

➲Test report contains full curves, test results, test conditions and sample parameters.

➲User logo and name can be added into test report.


Model Selection

1. Standard Package

Name

Model

Quantity

Unit

Remarks

Hysteresisgraph

MATS-2010SD/kXX

1

SET


Data acquisition card

PC-6616

1

PCS


Software

SMTest

1

SET


Industry computer

ADVANTECH IPC-510

1

SET


Monitor

LENOVO 18.5'

1

SET


Reference sample

Ring

1

PCS

With third party certificate

Standard cabinet

600mm*600mm*900mm

1

SET

For free


2. Optional

S/N

Name

Model

Main technical

Remarks

1

Solenoid

LXG-300

Max. Magnetic field 30kA/m

Measure the relative permeability ur of weak magnetic material.

2

Epstein Frame

ES-700


Measure the DC magnetic characteristics of silicon steel sheet.

3

Permeameter

Type A

Max. Magnetic field 120kA/m

Measure the saturation magnetic induction Bs of open circuit soft magnet sample.


Our Services

HUNAN LINKJOIN TECHNOLOGY CO., LTD. warrants each instrument of its manufacture to be free from defects in material and workmanship. Our obligation under this warranty is limited to servicing or adjusting any instrument returned to our factory for that purpose. The warranty period is 18 months. On returning the equipment under warranty, the buyer bears the costs for the shipment to LINKJOIN; LINKJOIN bears the costs for returning the device to the buyer. However, the buyer bears all the costs for shipment, taxes and duties, if the device is returned to LINKJOIN from abroad.


The warranty period begins on the date of delivery of the product or later on the date of installation of the product if the product is installed by LINKJOIN, the warranty period begins on the 31st day after delivery, provided that if you schedule or delay the LINKJOIN installation for more than 30 days after delivery.


LINKJOIN warrants the product only if it has been sold by an authorized LINKJOIN employee, sales representative, dealer or LINKJOIN headquarter.

The warranty period does not apply to defects of product result from improper or inadequate maintenance, repair or calibration;unauthorized modification or misuse; improper site preparation or maintenance. Caution: the hall probe is easy to damage; it's not in the warranty scope list.


Contact Us

HUNAN LINKJOIN TECHNOLOGY CO., LTD.

Address: 5F, Carve Out Building, Economic Development Zone, Loudi, Hunan, China

Mobile: +86-15197866786 E-mail: export@linkjoin.com

Tel: +86-738-8319167 Fax: +86-738-8326398

Website: http//www.linkjoin.net


http://www.hystograph.com/

Total0bar [View All]  Related Comments
 
More>other products

[ ProductsSearch ]  [ Send Fav ]  [ Share ]  [ Print ]  [ Send Report ]  [ Close ]

 