Hot search:
 

DC Generator High Voltage Tester

Click on the image to check the artwork
unit price: negotiable
min amount:
amount:
period for delivery: Consignment Deadline Days
area: Hubei
Expiry date : Long Effective
last update: 2023-11-06 05:37
view count: 252
enquiry
Company Profile
 
 
Product details

Product Introduction


 



ZGS series DC high voltage generator adopts high-frequency voltage doubler circuit, advanced PWM high-frequency pulse width modulation technology, closed-loop adjustment, and large voltage feedback, which greatly improves voltage stability. Use high-power IGBT devices and drive technology with excellent performance, and use special screen leakage, isolation and grounding measurements according to the theory of electromagnetic inclusiveness. The DC high-voltage generator has a high-quality, convenient and portable manner, and can withstand rated voltage discharge without damage. It has the characteristics of large output rate and small size, reliable overvoltage, overcurrent and zero closing protection functions, and 0.75 times voltage switching function. Using new technologies, new materials and new tools, it has the characteristics of large output power, small size and light weight, reliable overvoltage, overcurrent and zero position closing protection functions, with 0.75 times voltage latch function, and equipped with There is a timing relay, which can set a timing sound alarm during the test. The whole instrument is portable, easy to operate, safe and reliable.



 



It is mainly suitable for DC withstand voltage test or DC leakage current test for zinc oxide arresters, power cables, transformers, circuit breakers, generators and other high-voltage electrical equipment in power departments, industrial and mining, metallurgy, steel and other enterprise power departments.



 



1. Conductivity current test for valve arrester



2. DC withstand voltage test and leakage current measurement for power transformer



3. DC withstand voltage test and leakage current measurement for high voltage cable (35~500kV and below)



4. U1mA DC reference voltage test and 0.75U1mA leakage current test for zinc oxide arrester



 




Product Parameter


 


























































































































































Model



200/2



200/3



200/5



300/2



300/3



400/5



Rated voltage(kV)



200



200



200



300



300



400



Rated current(mA)



2



3



5



2



3



5



Rated power(W)



400



600



1000



600



900



2000



HV control unit(kg)



5.5



6



6.5



6.5



6.5



7.5



HV Cylinder weight(kg)



8.7



9



9



11



11



11.5



Cylinder height(mm)



970



970



970



1250



1250



1250



Voltage Accuracy



±(1.0%read+2b)



Accuracy Of Current



±(1.0%read+2b)



Ripple Factor



≤0.5%



Voltage Stability



When voltage change±10% stability≤1%



Overload Capacity



The no-load voltage can exceed the rated voltage by 10% for 10 minutes



Max charging current is 1.25 times rated current



Power Supply



Single phase current 50Hz 220V±10%



 



Working Way



Intermittent use: rated load for 30 minutes



1.1 times rated voltage: 10 minutes



Work Condition



temperature:-10℃~+40℃



relative humidity:less than 85% under 25℃, without moisture



altitude:1500M below



Capacitive Load Capacity



The capacity of the test object is unlimited



It can be charged at 1.5 times rated current



Structure



Electrical insulation voltage cylinder



Air insulation, no leakage



High Voltage Control Unit Feature

 



High accuracy 0.75UDC1mA One touch button(accuracy≤1.0%),Suitable for zinc oxide arrester test



Overvoltage protection using digital dialing switch, clear at a glance



Portable case, more convenient on site



Protection Function



Internal over voltage protection, internal over current protection



External overvoltage protection (protection voltage can be set), external overcurrent protection or breakdown protection



Internal power protection



Non-zero start protection



Timed sound alarm





Product Feature And Application


1. High precision and accurate measurement. The voltmeter on the control cabinet displays the voltage applied to load-tested equipment. No need to add a voltage divider, easy to wire. Equipped with high and low voltage ends to measure leakage current. High voltage end adopts round shield digital indication displaying, not worrying discharge shock. It has an excellent anti-jam function, which is suitable for field operation.



2. With stable voltage regulation, the regulation is smooth at  the whole range. The output voltage regulation adopts imported single multiturn potentiometer. Stable boost process and high accurate adjustment.



3. With negative polarity output, zero start, continuous adjustment, over-voltage, over-current, zero position, grounding protection, and special break-line protection functions. It can protect circuits automatic, perfect and reliable protection make safe operation.



4. Adopt advanced technology, medium frequency circuit and latest PWM pulse width modulation



technology and high power IGBT, which makes more stable high voltage output and smaller ripple factor.



5. With 0.75 times voltage conversion, convenient to test Zinc Oxide arrester.



6. Over-voltage setting use a digital dial switch, displaying data directly and visually (unit KV).



7. The sampling adopts a special nanosecond sensor and nanosecond optical isolation element, which can quickly and completely shut off the DC main circuit to protect the instrument from damage.



8. The cylinder adopts a new material, light and stable. With 3 support feet at the bottom, increase the stability. The outer surface of the cylinder is coated with special insulation materials, good electrical performance, strong moisture capacity, and no leakage.



9. Case is made of aluminum alloy with small volume, light weight, good appearance, more stable, easy to operate, full function, convenient to use on site.



 




Prodection Details









accessory






High voltage cylinder






Panel






discharging rod







 




Accessory


 































































Number



Name



Amount



Number



Name



Amount



1



Control cabinet



one



7



Fuse



two



2



High voltage doubler



one



8



Ground lead



one



3



High voltage cable



two



9



Micro-ampere meter



one



4



Discharging rod



one



10



Specification



one



5



Water resistance



one



11



Inspection Report



one



6



Power line



one



12



Certification



one




 




FAQ


 



1. Delivery: Fast delivery and Flexible mode of transportation

2. Payment: Choose payment terms and payment way you convenient

3. Sale service: 24-hour online contact, Choose the right model of equipment according to your request, give the best offer, support customization

4. Warranty period: All machine quality guarantees for one year and life-time technical support for you. Online response to customers' technical problems.



 






Production Line for DC hipot Tester




 







 







Customer Visit




 








On Site Service




 








Packing detail












Our service









01






Pre-sale service





Conduct product consultation, product promotion, and marketing activities, and technical support for customer needs.








02






Delivery service



Packing with wooden cases, provide different solutions of shipping way, accept different payment way. Save shipping cost and make sure the products arrive well.








03






After-sales service





Installation and commissioning of specific products; Respond to consumer questions, answer consumer inquiries, and deal with consumer comments.










http://www.sinohipot.com/

Total0bar [View All]  Related Comments
 
More>other products

[ ProductsSearch ]  [ Send Fav ]  [ Share ]  [ Print ]  [ Send Report ]  [ Close ]

 
Home | Products | Suppliers | News | Tradeshow | Sitemap | Message | RSS Feed