Steam Turbine Introduction

Steam turbine is a kind of rotary steam power plant. High temperature and high pressure steam passes through a fixed nozzle to become accelerated airflow and then is injected onto the blades to rotate the rotor equipped with blade rows while doing work externally. Steam turbine is the main equipment of modern thermal power plant, and is also used in metallurgical industry, chemical industry and ship power equipments.


I. Micro Steam Turbine(MST type)

1. Performance characteristics:

MST type steam turbine is a multi-stage steam turbine with 380 mm diameter impeller pitch circle and 1500-3000-5600-6500 rpm spindle speed. MST is a 1KW-500KW generator turbine unit that can use new steam or saturated temperature, with steam inlet pressure of only 0.15MPa and steam inlet temperature of saturated temperature. It is mainly used in the fields of energy comprehensive utilization such as ceramics, cement, power plants, chemical industry, chemical fiber, paper making, sugar making, iron and steel, waste treatment and enterprise-owned power stations, regional cogeneration, urban waste power stations, gas-steam combined cycle power generation, etc. The operation cost of the equipment is lower and the economic benefit is more remarkable. With the realization of the great rejuvenation of the Chinese nation, the "Chinese dream" and the cohesion of China's strength, the company will wholeheartedly provide first-class products and high-quality services to users and make due contributions.


2. Unit characteristics:

2.1. Wide working range, working pressure of 0.15Mpa working pressure of 4.9Mpa.

2.2. According to the power size and user requirements, single-layer and double-layer layout structures are designed.

2.3. This series of steam turbines are also called small steam turbines. They are easy to install and can also be installed quickly. After the equipment is transported to the user's site, the unit can be directly commissioned.

2.4. The adjustment modes include electric valve adjustment and digital electro-hydraulic (DEH) adjustment, which can be used selectively. The auxiliary devices include ETS, TSI and DCS. Auxiliary devices of small units can be ignored.

2.5. The steam source can be superheated steam or saturated steam.

2.6. The impeller blades of the unit are integrated, with high safety, long service life, no damage and no maintenance. The rotor is required to be used within the operating range.

2.7. The steam inlet pressure in the sample is a standard parameter, and a special steam turbine can be designed according to the actual parameters of the user.


3. Main Micro Steam Turbine models:

Model

Capacity (kw)

Speed(r/min)

Inlet

Consumption (kg/kw.h)

Exhaust Pressure (Mpa)

Weight (t)

Overall Dimensions LxWxH(mm)

Pressure (Mpa)

Temp. (

Flow (t/h)

N0.05-1.27

30-50

1500

1.27

300

0.3

6.2

0.06

0.33

506x211x621

N0.07-1.27

50-70

1500

1.27

300

0.5

6.42

0.06

0.43

560x251x652

N0.03-1.27

1-30

1500

1.27

300

0.2

6.67

0.06

0.16

322x211x351

N0.1-1.27

70-100

1500

1.27

300

0.6

6.36

0.06

0.55

706x403x666

NO.15-1.27

150

1500

1.27

300

1

6.35

0.05

0.62

735x432x701

N0.2-1.27

200

1500

1.27

300

1.3

6.36

0.05

0.7

821x456x801

N0.3-1.27

300

1500

1.27

300

1.9

6.33

0.05

0.76

850x475x855

N0.4-1.27

400

1500

1.27

300

2.7

6.63

0.05

0.81

933x520x900

N0.5-1.27

500

1500

1.27

300

3.1

6.25

0.05

0.88

988x622x956

N.55-1.27

550

1500

1.27

300

3.7

6.74

0.05

0.9

988x635x975

N0.6-1.27

600

1500

1.27

300

4

6.7

0.05

0.95

1010x755x1000

B0.05-1.27/0.2

30-50

1500

1.27

300

0.8

26.2

0.2

0.31

506x211x621

B0.07-1.27/0.2

50-70

1500

1.27

300

1.3

26.42

0.2

0.43

506x251x652

B0.03-1.27/0.2

1-30

1500

1.27

300

0

26.67

0.2

0.16

322x211x351

B0.1-1.27/0.2

70-100

1500

1.27

300

1.8

26.36

0.2

0.55

706x403x666

B0.15-1.27/0.2

150

1500

1.27

300

4

26.35

0.2

0.62

735x432x701

B0.2-1.27/0.2

200

1500

1.27

300

5.3

26.36

0.2

0.7

821x456x801

B0.3-1.27/0.2

300

1500

1.27

300

7.9

26.33

0.2

0.76

850x475x855

B0.4-1.27/0.2

400

1500

1.27

300

11

26.63

0.2

0.81

933x520x900

B0.5-1.27/0.2

500

1500

1.27

300

13

26.25

0.2

0.88

988x622x956

B0.55-1.27/0.2

550

1500

1.27

300

15

26.74

0.2

0.9

988x635x975

B0.6-1.27/0.2

600

1500

1.27

300

16

26.7

0.2

0.95

1010x755x1000


II. Industrial Steam Turbine

In industrial production, steam turbines are directly used as prime movers to drive some large mechanical equipment, such as large fans, feed water pump compressors and other equipment with relatively high power. Steam turbines for this purpose are called industrial steam turbines(nowadays some industrial steam turbine are also used in paper mill, sugar refinery for the purpose of generation and heat supply). Steam turbines that drive pumps, blowers, compressors and other machinery or steam turbines for power generation that are closely related to industrial production processes. Industrial steam turbines can not only use fuel or steam generated in boilers by-product heat energy in various industrial production processes, but also use residual steam in production processes.



The following is our main model of industrial steam turbine.


1. Condensing Turbine

Model

N1.5-2.35

N1.5-1.08

N1.5-0.638

N0.8-0.638

Code

D30

D1.5D

D1.5C

D0.8A

Type

Sub-MP single casing condensing turbine

LP singlecasing condensing turbine

LP singlecasing condensing turbine

LP singlecasing condensing turbine

Rated power(MW)

1.5

1.5

1.5

0.8

Max power (MW)

1.65

1.65

1.58

0.9

Rated speed(r/min)

6500

5600

5600

6500

Output speed(r/min)

1500

3000

3000

1500

Inlet pressure(MPa)

2.35

1.08

0.638

0.638

Inlet temperature (℃)

390

310

305

305

Rated inlet flow(t/h)

8.4

10.3

13

7

Max inlet flow(t/h)

9.7

11.4

13.7

7.9

Exhaust pressure(KPa)

9.3

9.3

9.3

9.3


Flow path series

Ⅱ+7

Ⅰ+7

7

7

Regeneration series

1CY

1CY

1CY

1CY

Feed water temperature(℃)

104

104

104

104

Condenser area(m2)

140

280

280

140

Outline dimension above operation

Floor(L×W×H/m

)

3.7×2.2×2.1

Single layer arrangement

4.1×3.4×2.4

Single layer arrangement

4.1×3.4×2.4

Single layer arrangement

3.7×2.2×2.1

Single layer arrangement

Body weight(t)

~10

~14

~13.5

~9.5

Max lift weight during inspection(t)

~1.9

~3.3

~3.2

~1.7

remark

With primary

gear reducer

With primary

gear reducer

With primary

gear reducer

With primary gear reducer


Model

N15-3.43

N12-3.43

N12-3.85

N6-3.43

Code

D15A

D26

D12H

D25

Type

MP single casing condensing turbine

MP single casing condensing turbine

MP singlecasing condensing turbine

MP single casing condensing turbine

Rated power(MW)

15

12

12

6


Max power(MW)

15.217

14.4

15

7.74


Rated speed(r/min)

3000

3000

3000

3000

Inlet pressure(MPa)

3.43

3.43

3.85

3.43


Inlet temperature(℃)

435

435

390

435


Rated inlet flow(t/h)

68.97

54.5

57.2

29


Max inlet flow(t/h)

70

66.8

70

38.8


Exhaust pressure(KPa)

6.86

7

6.86

8

Flow path series

Ⅱ+11

Ⅱ+11

Ⅱ+11

Ⅱ+9

Regeneration series

1GJ+1CY+1DJ

1GJ+1CY+1DJ

1CY+1DJ

1GJ+1CY+1DJ

Feed water temperature(℃)

170.2

163.8

130.9

164

Condenser area(m2)

1100

1000

1200

560

Outline dimension above operation floor(L×W×H/m)

5.37×3.59×3.7

5.3×3.6×3.5

5.37×3.59×3.7

4.8×2.7×2.7

Body weight(t)

~49

~49

~49

~38

Max lift weight

during inspection(t)

~16

~16

~16

~8

remark






2. Extraction & condensing turbine

Model

C15-4.91/0.98

C12-3.43/0.98

C12-3.43/0.49

C6-3.43/0.49

Code

J15A

D12M

J12E

J6F

Type

Sub-HP single extraction turbine

MP single casing

Extraction turbine

MP single

Casing

Extraction

turbine

MP single casing

extraction turbine

Rated power(MW)

15

12

12

6

Max power(MW)

18

15

15

8

Rated speed(r/min)

3000

3000

3000

3000

Inlet pressure(MPa

)

4.91

3.43

3.43

3.43

Inlet temperature(℃)

470

435

435

435

Rated inlet flow(t/h

)

102

99/ 56( pure condensing )

97

57.5

Max inlet flow(t/h)

137

120

120

65

Exhaust pressure(KPa)

5.5

5.39

8

8

Extraction pressure(MPa)

0.98

0.98

0.49

0.49

Extraction temperature(℃)

300

307.1

209

209

Rated extraction flow(t/h)

50

50

60

45

Max extraction flow(t/h)

80

80

80

45

Flow path series

Ⅱ+11

Ⅱ+11

Ⅱ+11

Ⅱ+9

Regeneration series

1GJ+1CY+1DJ

1GJ+1CY+1DJ

1GJ+1CY+1DJ

1GJ+1CY+1DJ

Feed water temperature(℃)

154

173.8

172

145

Condenser area(m2)

1100

1470

1000

560

Body weight(t)

~65

~62

~60

~41

remark






Model

C12-8.83/0.98

C12-4.91/1.08

C12-4.91/0.98

C12-4.1/0.35

Code

D12J

J12A

J12C

D12G

Type


HP single extraction turbine

Sub-HP single extraction turbine

Sub-HP single extraction turbine

MP single casing

Extraction

turbine

Rated power(MW)

12

12

12

12

Max power(MW)

13

15

15

15

Rated speed(r/min)

3000

3000

3000

3000

Inlet pressure(MPa)

8.83

4.91

4.91

4.1

Inlet temperature(℃)

535

470

435

330

Rated inlet flow(t/h)

83.8

91.1( pure condensing 50.2)

92( pure condensing 52.5)

57.4( pure condensing )

Max inlet flow(t/h)

99

130

122.5

100

Exhaust pressure(KPa)

4

6.86

4.9

9.81

Extraction pressure(MPa)

0.98

1.08

0.98

0.35

Extraction temperature(℃)

279

312.5

273

138.9

Rated extraction flow(t/h)

50

50

50

32

Max extraction flow(t/h)

70

80

80

70

Flow path series

Ⅰ+18

Ⅱ+11

Ⅱ+11

Ⅱ+10

Regeneration series

2GJ+1CY+3DJ

1GJ+1CY+1DJ

1CY+1DJ

No

Feed water temperature(℃)

213

150.5

150

52.8

Condenser area(m2 )

1150

1100

1100

1100

Body weight (t)

~119.5

~62

~62

~65

remark






3. Back pressure turbine

Model

B1.5-2.35/0.29

B1-2.35/0.59

B0.75-1.28/0.29

B0.45-1.28/0.29

Code

D10-1.5

D10-1.0

D08

DJ02

Type

Sub-MP single casing back pressure turbine

Sub-MP single casing back pressure turbine

LP single casing back pressure turbine

LP single casing back pressure turbine

Rated power(MW)

1.5

1

0.75

0.45

Max power(MW)

1.65

1.2

0.81

0.5

Rated speed(r/min)

6500

6500

6500

3000

Output speed(r/min)

1500

1500

1500

3000

Inlet pressure(MPa)

2.35

2.35

1.28

1.28

Inlet temperature(℃)

390

390

340

340

Rated inlet flow (t/h)

18.9

17.6

13.6

13.5

Max inlet flow(t/h)

20.8

21.2

14.7

15

Exhaust pressure(MPa)

0.29

0.59

0.29

0.29

Exhaust temperature(℃)

220

265

225

272

Flow path series

Outline dimension

above operation floor(L×W×H/m

)

2.8×2.0×1.9

2.8×2.0×1.9

2.8×2.0×1.9

3.4×1.76×1.43

Body weight (t)

6

6

5.5

3.1

Max lift weight during inspection (t)

~0.9

~0.9

~0.9

~0.45

Remark

With primary gear reducer

With primary gear reducer

With primary gear reducer

Single layer

arrangement


Model

B6-4.91/1.9

B6-4.91/1.08

B6-3.43/0.98

B6-3.43/0.49

Code

D6F

J6A

D21

D11

Type

Sub-HP single casing back pressure turbine

Sub-HP single

casing back

pressure

turbine

MP single casing back pressure turbine

MP single casing back pressure turbine

Rated power(MW)

6

6

6

6

Max power(MW)

6

9

6.27

6.62

Rated speed(r/min)

3000

3000

3000

3000

Inlet pressure (MPa)

4.91

4.91

3.43

3.43

Inlet temperature(℃)

475

435

435

435

Rated inlet flow(t/h )

115

83

95

63.5

Max inlet flow(t/h )

127

120

99.3

70

Exhaust pressure(MPa )

1.9

1.08

0.98

0.49

Exhaust temperature(℃)

367.7

281.7

307

243

Flow path series

Ⅱ+2

Ⅱ+2

Ⅱ+2

Ⅱ+4

Outline dimension above operation floor(L×W×H/m)

4.52×1.8×2.92

4.31×1.8×2.75

4.1×2.0×2.4

4.1×2.0×2.7

Body weight (t)

~30

~30

~25

~28

Max lift weight during inspection (t)

~5

~4.1

~7.2

~7.5

remark






4. Extraction & back pressure turbine

Model

CB25-8.83/1.4/0.8

CB20-12.8/6.6/2.5

CB12-3.43/0.84/0.49

Code

D25L

D20A

J12D

Type

HP extraction back pressure turbine

Super HP extraction back pressure turbine

MP extraction

back pressure turbine

Rated power(MW)

25

20

12

Max power(MW)

30

22.9

13.23

Rated speed(r/min)

3000

3000

3000

Inlet pressure (MPa)

8.83

12.8

3.43

Inlet temperature(℃)

535

555

435

Rated inlet flow(t/h )

213

450

130

Max inlet flow(t/h)

248

450

130

Exhaust pressure(MPa )

0.8

2.5

0.49

Exhaust flow(t/h )

89.6

236

102.9

Extraction pressure(MPa)

1.4

6.6

0.84

Extraction temperature(℃ )

311.4

470

287

Rated extraction flow(t/h )

100

160

25

Max extraction flow(t/h )

118

280

40

Flow path series

Ⅰ+10

Ⅰ+3+Ⅰ+3

Ⅱ+4

Body weight (t)

~105

~115

~40

remark





Ⅲ. Thermal Power Steam Turbine

Dongturbo's leading product, thermal power turbine, has a complete product series of various types or combinations such as condensation, air cooling and heat supply. The power and parameters of the unit have developed from 1MW high-pressure turbine to 300 MW ultra-supercritical turbine. It has mature, reliable and advanced air cooling and heat supply technologies and complete auxiliary equipment, and is in the leading position in China.



The following is our main models of thermal power steam turbine.


1. Typical Small Combined Heat and Power Turbine Units 

1.1. Typical straight condensing units  

Model

N110-8.83

N65-8.83

NZK60-1.9

N25-3.43

Product code

D110B (Riau, Indonesia)

D65C (Sulawesi)

A163A (Shenhua Ningxia Coal Industry)

D25H (Jiujiang Pinggang)

Type

High-pressure, double-casing, double-flow condensing turbine

High-temperature, high-pressure, single-casing condensing turbine

Sub-intermediate pressure, single-casing, air-cooled condensing turbine

Intermediate pressure, single-casing condensing turbine

Rated/Max. power, MW

110/117

65/69

60/65

25/27.5

Steam admission pressure, MPa/ Temperature, ℃

8.83/535

8.83/535

1.9/335

3.43/435

Rated/Max. steam admission flow, t/h

398/427

243/260

297/320

102/113

Back pressure, KPa

8.2

6.28

14

9.5

Regenerative system

2GJ+1CY+4DJ

2GJ+1CY+3DJ

NO

NO

Quantity

2t

2t

4t

1t


1.2. Typical extraction condensing units

Model

CC125/96-8.83/4.8/1.1

CC60-8.83/1.27/0.49

CCZK50-11.9/4.6/1.4

CC25-8.83/4.1/1.28

Product code

D125C (Chongqing Chemical & Phamaceutical)

D60L (Guangzhi Haizhu)

A454A (Shenhua Ningxia Coal Industry)

D25J (Gangcheng Thermal Power)

Type

High-pressure, double-casing, double-extraction condensing turbine

High-pressure, single-casing, double-extraction condensing turbine

Ultra-high pressure, single-casing, double-extraction, air-cooled condensing turbine

High-pressure, single-casing, double-extraction condensing turbine

Rated/Max. power, MW

125/130

60/63

50/60

25/30

Steam admission pressure, MPa/ Temperature, ℃

8.83/535

8.83/535

11.9/535

8.83/535

Rated/Max. steam admission flow, t/h

520/550

218/350

326/352

93/262

Back pressure, KPa

6.3

7.0

14

6.6

Extraction pressure, MPa

4.8/1.1

1.27/0.49

4.6/1.4

4.1/1.28

Rated extraction flow, t/h

82/125

73/120

150/50

60/80

Max. extraction flow, t/h

110/160

100/140

200/100

70/100

Regenerative system

2GJ+1CY+3DJ

2GJ+1CY+3DJ

NO

2GJ+1CY+3DJ


1.3. Typical backpressure units 

Model

B60-8.83/0.981

B46-8.83/1.5

B30-8.83/0.785

Product code

D60Q (Nine Dragons Paper)

Erdos (D46A)

D30C (Xinjiang Meihua)

Type

High-temperature, high-pressure,
single-casing, backpressure

High-temperature, high-pressure,
single-casing, backpressure

High-temperature, high-pressure,
single-casing, backpressure

Power, MW

60/63

46/48.6

30/32

Steam admission pressure, MPa/ Temperature, ℃

8.83/535

8.83/535

8.83/535

Steam admission flow, t/h

448/470

418.8/440

233.6/254.5

Exhaust pressure, MPa

0.981

1.5

0.785

Regenerative system

2GJ+1CY

2GJ+1CY

2GJ+1CY

Quantity

1

2

2


1.4. Typical backpressure extraction units 

Model

CB50-10.5/3.8/1.3

CB40-8.83/2.8/1.275

CB30-8.83/3.53/1.37

Product code

A355A (Huanneg Yingkou)

D40B (Songhuajiang)

D30F (Juhua Group)

Type

High-pressure, single-casing, extraction backpressure

High-temperature, high-pressure, single-casing, extraction backpressure

High-temperature, high-pressure, single-casing, extraction backpressure

Power, MW

58.6/68.9

41/43

28.2/30.4

Steam admission pressure, MPa/ Temperature, ℃

10.5/565

8.83/535

8.83/535

Steam admission flow, t/h

470/495

417.6/450

280/300

Extraction pressure, MPa

3.8

2.8

3.53

Exhaust pressure, MPa

1.3

1.275

1.37

Extraction flow, t/h

82/100

140/180

50/60.4

Regenerative system

2GJ+1CY+1 steam pump

2GJ+1CY

2GJ+1CY

Quantity

2

2

1


2. Typical Small Reheat Turbine Units

2.1. Project background and significance

• With rapid development of the world economy and increasing shortage of the industrial energy, national policies for energy conservation and emission reduction are greatly implemented to move the industrial energy towards efficient, environment-friendly and sustainable development.

• High-parameter, single-reheat and single-casing turbine units emerge at the right time to greatly improve the unit economical efficiency, fully use abundant waste heat generated in various industrial sectors, achieve energy conservation and emission reduction, and reduce costs arising from manufacturing and civil works.

• To meet market demand and achieve energy conservation and emission reduction, Dongfang Turbine Co., Ltd. has independently and innovatively developed the 65 MW ultra-high-pressure single-casing single-reheat condensing turbine with the support of purchase orders.


2.2. Technical advance

• Compared with the conventional high-temperature, high-pressure, non-reheat, straight condensing 65 MW turbine, Dongfang 65 MW single-casing reheat unit has low thermal consumption.

• Compared with the ultra-high-pressure, high-temperature, reheat straight condensing 135 MW turbine in double-casing structure, the single-casing reheat turbine lowers the costs arising from manufacturing and civil works, and enhances the comprehensive competitiveness.

• Compared with the ultra-high-pressure, high-temperature, reheat straight condensing 135 MW turbine in double-casing structure, the single-casing reheat turbine lowers the costs arising from manufacturing and civil works, and enhances the comprehensive competitiveness.

• More importantly, the first unit shows excellent performance indicators and proves high economical efficiency and safety since being put into operation.


2.3. Parameters of Reheat Steam Turbine

Item

30 MW ultra-high-pressure, single-reheat condensing turbine

40 MW ultra-high-pressure, single-reheat condensing turbine

65MW ultra-high-pressure, single-reheat condensing turbine

65MW ultra-high-pressure, single-reheat condensing turbine

Rated power, MW

30

40

5050

65

Steam admission pressure, MPa.a

13.2

13.2

8.83

13.2

Steam admission temperature, ℃

535

538

538

538

Reheat temperature, ℃

535

538

566

538

Rated steam admission flow, t/h

92

123.2

220

200.5

Rated backpressure, Kpa

4.9

4.9

4.9

4.9

Steam consumption in rated working condition, kg/kW.h

3.066

3.079

2.89

3.084

Rated speed

5350

5350

Feed water temperature, ℃

220.4

236.2

229.3

248.4

Last-stage blade height, mm

411.2

420

736.6

736.6

Annual operation hours, h

8000

8000

8000

8000


Ⅳ. Advantage

1. Impulse steam turbine, Enlarged base, Fast loading structure

2. Packaged oil container

3. Delivery the whole steam turbine without opening the cylinder to minimize the time of on-site installation time

4. High efficiency, Strong working ability, Large power headroom

5. Simple and reliable structure, Sensitive start, Stable le operation.

6. Good performance with variable speed and conditions

7. Rotor and dynamic blade with advanced design technology

8. High speed dynamic balance and the thermal load test in factory

9.Advanced and reliable control technology


http://www.chinaturbo.net/

Total0bar [View All]  Related Comments
 
More>other products

[ ProductsSearch ]  [ Send Fav ]  [ Share ]  [ Print ]  [ Send Report ]  [ Close ]

 
Home | Products | Suppliers | News | Tradeshow | Sitemap | Message | RSS Feed